SenTech STC-400 SeriesL Especificações Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
Sentech STC-400 Series Application Manual
Toll Free (877) 736-8324 Fax (972) 446-0056 www.SentechAmerica.com
SEN
TECH
Shutter Speed Switch Settings
Mode EIA CCIR SW1 SW2 SW3 SW4 SW5
Field 1/30 1/25 Either Either Either OFF OFF
Field 1/60 1/50 OFF OFF OFF ON OFF
Field 1/100 1/120 ON OFF OFF ON OFF
Field 1/250 1/250 OFF ON OFF ON OFF
Field 1/500 1/500 ON ON OFF ON OFF
Field 1/1,000 1/1,000 OFF OFF ON ON OFF
Field 1/2,000 1/2,000 ON OFF ON ON OFF
Field 1/4,000 1/4,000 OFF ON ON ON OFF
Field 1/10,000 1/10,000 ON ON ON ON OFF
(2) Field Integration Mode
(3) Setting Gamma (1.0 or 0.45)
Gamma = 1.0 SW6 = ON
Gamma = 0.45 SW6 = OFF